Standing next to something? Write down what it says before you walk away.
Servicing schedules are recorded against the church itself, and this build has no database behind the maintenance desk. Nothing typed here would be kept, so the form is not offered.
Out of certificate
3
The same as a week ago.
A certificate on file has expired. Operating uncertificated equipment is its own problem, not a late service.
Overdue
5
The same as a week ago.
Counted from each regime's own trigger, on the day it fell due.
Cannot be judged
2
The same as a week ago.
Waiting on a reading or a certificate. Unknown is not late, and it is counted apart from anything that is.
Before Sunday
2
On things somebody flagged Sunday-critical, for 18 Oct 2026.
The same as a week ago.
Sunday-critical is a flag with a name on it, never worked out from a title.
Servicing done on time
No figure
No completion can be judged yet, so there is no compliance figure — not a figure of zero. The window is October to December 2026.
On time means the work was completed within 10% of the regime interval after the day it fell due.
Before Sunday
Only work on things somebody flagged Sunday-critical, and every chip says who flagged it.
Standby generator, 30 kVA — Generator service, every 250 hours
Overdue · Roughly 76 days ago, at the rate between the last two readings. Service is due at 1,500 hours.
Highfield
Channel 14 cutting out intermittently
WO-0305 · Sound mixer, 32 channel · Highfield · James Nkosi
This week, by site
Ordered the way the walk is, not the way the urgency is.
Borrowdale
Water heater — Water heater service
Overdue · Due 4 Mar 2026, 224 days ago (set 5 Sep 2025 and has produced nothing, every 180 days).
Borrowdale
Set 5 Sep 2025, and has produced nothing. Nothing has ever been raised against it.
Chitungwiza
Fire extinguishers, Chitungwiza — Extinguisher service certificate
Out of certificate · The certificate from Harare Fire Protection expired on 14 Jun 2026, 122 days ago.
Chitungwiza
Set 15 Jun 2025, and has produced nothing. Nothing has ever been raised against it.
Highfield
Standby generator, 30 kVA — Generator service, every 250 hours
Overdue · Roughly 76 days ago, at the rate between the last two readings. Service is due at 1,500 hours.
Highfield
Borehole pump — Borehole pump service, every 500 hours
Cannot be judged · Only one reading has been recorded. A rate needs two, so there is no estimate — not a rougher one. Unknown is not the same as late.
Highfield
Set 20 Jan 2026, and has produced nothing. Nothing has ever been raised against it.
Fire extinguishers, Fellowship Hall — Extinguisher service certificate
Out of certificate · The certificate from Harare Fire Protection expired on 14 May 2026, 153 days ago.
Highfield
Set 15 May 2025, and has produced nothing. Nothing has ever been raised against it.
Minibus, 25 seats — Minibus service, every 5,000 km
Overdue · The meter read 9,200 km on 1 Jun 2026; service is due at 9,000 km.
Highfield
Minibus, 25 seats — Certificate of fitness
Out of certificate · The certificate from Vehicle Inspection Department expired on 14 Jun 2026, 122 days ago.
Highfield
Set 15 Dec 2025, and has produced nothing. Nothing has ever been raised against it.
Fellowship Hall air conditioning — Air conditioning service
Overdue · Due 13 May 2026, 154 days ago (set 12 Feb 2026 and has produced nothing, every 90 days).
Highfield
Set 12 Feb 2026, and has produced nothing. Nothing has ever been raised against it.
Minibus service — 9,200 km, past the service point
WO-0304 · Minibus, 25 seats · Highfield · Peter Kamau
Channel 14 cutting out intermittently
WO-0305 · Sound mixer, 32 channel · Highfield · James Nkosi
Not on the register
This site has no name on the church tree, so its own id is shown.
The pump house door will not lock
WO-0307 · not on the register yet · Not on the register · nobody has taken it